Page 48 of 81. Showing 810 results (0.049 seconds)
About signature ID codes
and place the code as a Prinergy variable mark. Use the signature ID code in a Prinergy sheet mark or slug line mark. The signature ID code is applied to an imposition when it is imported into a Prinergy job. When you create the imposed output, Prinergy replaces the variable mark, sheet mark, or slug linePages pane (Pages view)
, and 90 CCW (counter-clockwise). If the file is not a PDF file, the orientation appears as N/A. <process template> The name of the process template group … of degrees that the page is rotated. Select from 0, 90 CW (clockwise), 180, and 90 CCW (counter-clockwise). If the file is not a PDF file, the orientationPages pane (Signatures view)
of degrees that the page is rotated. Select from 0, 90 CW (clockwise), 180, and 90 CCW (counter-clockwise). If the file is not a PDF file, the orientation appears as N … /A. Orientation (°) The number of degrees that the page is rotated. Select from 0, 90 CW (clockwise), 180, and 90 CCW (counter-clockwise). If the fileplate line
characteristics of platesetters and variations in processor chemistry are two variables that can cause different plating output from a plate line. For example, if you … químicos del procesador son dos variables que pueden causar diferentes salidas de plancha de una línea de plancha. Por ejemplo, si tiene dos filmadoras deRBA best practices
in global or rule set variables. Some examples are e-mail addresses, server names, files shares. A global variable should be used if the value is going to be referenced across multiple rule sets. A rule set variable should be used if it is only going to be referenced from that rule set. By encapsulating them in a variableAppendix - Assessment answers
this? A global or rule set variable can be used to encapsulate external values. A global variable should be used if the value is going to be referenced across multiple rule sets. A rule set variable should be used if it is only going to be referenced from that rule set. It is a good idea as it simplifies maintenanceSetting a process template to use marks file
are typing the path name directly in the box, use the variable %system% as part of the path name to denote the%AraxiHome%\CreoAraxi folder on your Prinergy system … nom du chemin d'accès directement dans le champ, intégrez la variable %system% au nom du chemin d'accès pour représenter le dossier %AraxiHome%\CreoAraxi dansBar codes in custom marks
. The finishing equipment scans the coded text-mark variables in each mark to check that all the signatures belong to the same job and are in the correct sequence. Note … represented by the bar code symbols. Each mark contains the job and signature ID text-mark variables, with a defined number of digits allocated for each variableTypes of JTPs
worddavd41cc1bc92dd5e895549125bdf4c9e9a.png Marks Replaces variable text in text marks during output Marks worddavebd3a46411afc67d8fcbe9a4ead17f2d.png Normalize … worddavd41cc1bc92dd5e895549125bdf4c9e9a.png Marcas Sustituye el texto de las marcas de variables de texto durante la salida Marcas worddavebd3a46411afc67d8fcbe9a4ead17f2d.pngStarting a rule remotely with the Raise Event tool
> [-waitport <waitport>]] Replace the variables in the command using the following guidelines: Variable Description ruleset The full path of the rule … die Variablen im Befehl, und befolgen Sie dabei die folgenden Richtlinien: Variable Beschreibung Regelsammlung Der vollständige Pfad der