Sv translation
languageen

There is an update to Double-take 8.4 available for Prinergy 9.5. Please contact your regional support office and reference Knowledge Base Answer ID 75659 to have it installed.

Double-take 8.2 should continue to work with Prinergy 9.5, but 8.4 is the officially qualified version. The DT 8.4 update fixes the issue described in Answer ID 75473, so its recommended to update ASAP.

Before updating, you will need to ensure you are eligible for a new Double-Take 8.4 license. Please contact your regional support office with your Double-Take 8.2 and Prinergy serial number, and they will confirm your eligibility.

When upgrading the primary server running on Windows 2016/2019 operating system with Double-Take 8.2 /  8.4, perform the tasks listed in the specified order.

...

Note you can perform the steps below when upgrading to Prinergy 9.5 and then upgrade double-take 8.4 after

  1. Go to Windows Services on both primary and EPM servers and STOP the Double-Take and Double-Take Management services and CHANGE them both to Disabled.
  2. Upgrade the primary server.
  3. Upgrade the secondary (failover) server.
  4. Go to Windows Services on both primary and EPM servers and CHANGE the Double-Take service to Automatic and start it, then CHANGE the Double-Take Management service to Automatic (Delayed Start) and start it.

Important reminder: do not start PrinergyDBRestore !!!!!!!!!

For more detailed instructions on connecting the PrinergyDB replication job, see the EPM (Emergency Platemaking) and Hot Standby with Double-Take for Prinergy 9.x Installation Guide
Note: After completing the upgrade of all servers, a failover test must be completed to ensure the hot standby support is working correctly.

Sv translation
languagede

Für Prinergy 9.5 ist ein Update für Double-Take 8.4 verfügbar. Wenden Sie sich an Ihre regionale Zweigstelle für Support, und geben Sie die Knowledge Base Antwort-ID 75659 an, um die Installation zu überprüfen.

Double-Take 8.2 sollte weiterhin mit Prinergy 9.5 funktionieren, aber 8.4 ist die offiziell qualifizierte Version. Das DT 8.4-Update behebt das in Antwort-ID 75473 beschriebene Problem, daher wird empfohlen, das Update so schnell wie möglich durchzuführen.

Vor der Aktualisierung müssen Sie sicherstellen, dass Sie Anspruch auf eine neue Double-Take 8.4-Lizenz haben. Bitte wenden Sie sich mit der Double-Take 8.2 und der Prinergy-Seriennummer an Ihre regionale Zweigstelle für Support, um Ihre Berechtigung zu bestätigen.

Wenn Sie den Hauptserver auf einem Windows 2016-Betriebssystem mit Double-Take 8.2/8.4 aktualisieren, führen Sie die beschriebenen Schritte in der angegebenen Reihenfolge aus.

Hinweis: Sie können die folgenden Schritte ausführen, wenn Sie auf Prinergy 9.5 aktualisieren und danach auf Double-Take 8.4 aktualisieren

  1. Trennen Sie den PrinergyDB-Replikationsjob auf dem Hauptserver:
    1. Öffnen Sie die Double-Take-Konsole: Rufen Sie Start > Programme > Double-Take-Konsole auf, oder doppelklicken Sie auf Console UI.exe unter C:\Program Files\Vision Solutions\Double-Take\Console.
    2. Lizenzen aufzeichnen.
    3. Wählen Sie im Menü Gehe zu die Option Jobs verwalten.
    4. Klicken Sie mit der rechten Maustaste auf den Job PrinergyDb, und wählen Sie Anhalten.
  2. Upgraden Sie den Hauptserver.
  3. Upgraden Sie den Zusatzserver (Sicherungsserver).
  4. Verbinden Sie den PrinergyDB-Replikationsjob erneut:
    1. Öffnen Sie auf dem Hauptserver die Double-Take-Konsole: Rufen Sie Start > Programme > Double-Take-Konsole auf, oder doppelklicken Sie auf Console UI.exe unter C

...

    1. :\Program Files\Vision Solutions\Double-Take\Console.
    2. Wählen Sie im Menü Gehe zu die Option Jobs verwalten.
    3. Klicken Sie mit der rechten Maustaste auf jeden der Jobs PrinergyDB & PrinergyDBRestore und dann auf „Löschen“.
    4. Öffnen Sie die DT-Installationsanleitung: https://resources.kodak.com/services/132b351/en_US/software_solutions/workflow_software/prinergy/downloads/version95/EPM_and_Hot_Standby_with_Double-Take_for_Prinergy_9.5_Installation_Guide_2022.

...

    1. pdf
      1. Hinweis: Das DT-Installationshandbuch steht nur Mitarbeitern von Kodak zur Verfügung. Wenden Sie sich bitte an Ihre regionale Zweigstelle für Support.
    2. Seite 14 oder unter dem Header: Erstellen eines Replikationssatzes für Oracle-Datenbanken, Erstellen neuer Jobs
    3. Konfigurieren Sie beide Jobs, PrinergyDB und PrinergyDBRestore. Anweisungen zum Implementieren unten auf Seite 16 oder unter dem Header: Konfiguration der Datenbankreplikation in der Double-Take-Konsole – Spiegeln, Überprüfen und Zuordnen verwaister Dateien/Pfade)
    4. Klicken Sie zum Fortfahren auf OK

Wichtige Erinnerung: Starten Sie PrinergyDBRestore nicht!!!!!!!!!

Ausführlichere Anleitungen zum Verbinden des PrinergyDB-Replikationsjobs finden Sie im Installationshandbuch für EPM (Emergency Platemaking) und Hot Standby mit Double-Take für Prinergy 9.x.
Hinweis: Nachdem dem Upgrade aller Server muss ein Sicherungstest ausgeführt werden, damit sichergestellt wird, dass der Hot-Standby-Support ordnungsgemäß funktioniert.

Sv translation
languagees

Hay una actualización de Double-Take 8.4 disponible para Prinergy 9.5. Póngase en contacto con el servicio de asistencia de su región y consulte la respuesta con el ID 75659 de la base de conocimientos para instalarla.

Double-Take 8.2 debería seguir funcionando con Prinergy 9.5, pero la versión oficialmente compatible es la 8.4. La actualización DT 8.4 corrige el problema descrito en la respuesta con el ID 75473, así que es conveniente aplicarla cuanto antes.

Antes de realizar la actualización, deberá asegurarse de que reúne los requisitos para obtener una nueva licencia de Double-Take 8.4. Póngase en contacto con el servicio de asistencia de su región e indique su número de serie de Double-Take 8.2 y Prinergy para que le confirmen si puede obtenerla.

Al actualizar el servidor principal con sistema operativo Windows 2016/2019 y Double-Take 8.2/8.4, realice las tareas indicadas en el orden especificado.

Puede realizar los pasos siguientes al actualizar a Prinergy 9.5 y actualizar a Double-Take 8.4 después.

  1. Desconecte el trabajo de replicación de Prinergy DB del servidor principal:
    1. Abra la consola Double-Take: Vaya a Inicio > Todas las aplicaciones > Consola Double-Take o haga doble clic en Consola UI.exe en C:\Archivos de programa\Vision Solutions\Double-Take\Console.
    2. Registre las licencias.
    3. En el menú Ir, seleccione Gestionar trabajos.
    4. Haga clic con el botón secundario en el trabajo PrinergyDb y seleccione Detener.
  2. Actualice el servidor principal.
  3. Actualice el servidor secundario (recuperación tras fallo).
  4. Vuelva a conectar el trabajo de replicación de PrinergyDB:
    1. En el servidor principal, abra la consola Double-Take: Vaya a Inicio > Todas las aplicaciones > Consola Double-Take o haga doble clic en Consola UI.exe en C:\Archivos de programa\Vision Solutions\Double-Take\Console.
    2. En el menú Ir, seleccione Gestionar trabajos.
    3. Haga clic con el botón secundario en los trabajos PrinergyDB y PrinergyDBRestore, y elimínelos.
    4. Abra la guía de instalación de DT: https://resources.kodak.com/services/132b351/en_US/software_solutions/workflow_software/prinergy/docs/version95/EPM_and_Hot_Standby_with_Double-Take_for_Prinergy_9.5_Installation_Guide_2022.pdf
      1. Nota: La guía de instalación de DT solo está disponible para el personal de Kodak. Póngase en contacto con el servicio de asistencia de su región.
    5. Página 14 o debajo del encabezado: Al crear un conjunto de replicación de base de datos de Oracle, cree nuevos trabajos.
    6. Configure ambos trabajos: PrinergyDB y PrinergyDBRestore. Instrucciones de implementación en la parte inferior de la página 16 o debajo del encabezado: Configure la replicación de la base de datos en Consola de Double-Take: Replicar, Verificar y Archivo huérfano / Asignación de ruta)
    7. Haga clic en Aceptar para guardar.

Recordatorio importante: No inicie PrinergyDBRestore.

Para obtener instrucciones más detalladas sobre la conexión del trabajo de replicación PrinergyDB, consulte la guía de instalación de EPM (Emergency Platemaking) y Hot Standby con Double-Take para Prinergy 9.x.
Nota: Tras completar la actualización de todos los servidores, deberá completar una prueba de recuperación tras fallo para garantizar la compatibilidad con Hot Standby.

Sv translation
languagefr

Une mise à jour de Double-Take 8.4 est disponible pour Prinergy 9.5. Veuillez contacter votre bureau d'assistance régional et consulter la réponse ID 75659 de la base de connaissances pour l'installer.

La version Double-Take 8.2 devrait continuer à fonctionner avec Prinergy 9.5, mais la version 8.4 est officiellement approuvée. La mise à jour du DT 8.4 corrige le problème décrit dans la réponse ID 75473. Il est donc recommandé d'effectuer la mise à jour au plus vite.

Avant la mise à jour, vous devez vous assurer que vous êtes admissible à une nouvelle licence Double-Take 8.4. Veuillez contacter votre bureau d'assistance régional en indiquant votre numéro de série Double-Take 8.2 et Prinergy. Il confirmera votre admissibilité.

Lorsque vous mettez à niveau le serveur principal sur un système d'exploitation Windows 2016/2019 avec Double-Take 8.2/ 8.4, réalisez les tâches répertoriées dans l'ordre spécifié.

Remarque : vous pouvez effectuer les étapes ci-dessous lors de la mise à niveau vers Prinergy 9.5, puis mettre à jour Double-Take 8.4

  1. Déconnectez le travail de réplication PrinergyDB sur le serveur principal :
    1. Ouvrez la console Double-Take : Accédez à Démarrer > Toutes les applications > Console Double-Take ou double-cliquez sur Console UI.exe dans C:\Program Files\Vision Solutions\Double-Take\Console.
    2. Enregistrez les licences.
    3. Dans le menu Aller, sélectionnez Gérer les travaux.
    4. Cliquez sur le travail PrinergyDB et sélectionnez Arrêter.
  2. Mettez à niveau le serveur principal.
  3. Mettez à niveau le serveur secondaire (de basculement).
  4. Reconnectez le travail de réplication PrinergyDB :
    1. Sur le serveur principal, ouvrez la console Double-Take : Accédez à Démarrer > Toutes les applications > Console Double-Take ou double-cliquez sur Console UI.exe dans C

...

    1. :\Program Files\Vision Solutions\Double-Take\Console.

...

  1. Note: the Double Take installation guide below, is an update to Double-take 8.4 (fixes an issue where DT doesn't start after server reboot). Double 8.2 will continue to work in Prinergy 9.5, but its highly recommended to update to 8.4.
  2. Before updating, please contact Carbonite Support with your 8.2 serial number, to ensure you are eligible and can retrieve a new Double-Take 8.4 license.
    1. Dans le menu Aller, sélectionnez Gérer les travaux.
    2. Cliquez avec le bouton droit de la souris sur chacun des travaux, PrinergyDB et PrinergyDBRestore, puis supprimez-les.
    3. Ouvrir le Guide d'installation de DT : https://resources.kodak.com/services/132b351/en_US/software_solutions/workflow_software/prinergy/downloads/version95/EPM_and_Hot_Standby_with_Double-Take_for_Prinergy_9.5_Installation_Guide_2022.pdf
      1. Remarque : le guide d'installation DT est uniquement disponible pour le personnel Kodak. Veuillez appeler votre bureau d'assistance régional.
    4. Page 14 ou sous l'en-tête : Création d'un jeu de réplication de base de données Oracle, création de nouveaux travaux
    5. Configurez les deux travaux, PrinergyDB et PrinergyDBRestore. Mettre en œuvre les instructions au bas de la page 16 ou sous l'en-tête : Configuration de la réplication de base de données dans la console Double-Take – Mise en miroir, vérification et mappage de fichier orphelin/chemin d'accès)
    6. Cliquez sur OK pour enregistrer

Rappel important : Ne démarrez pas PrinergyDBRestore !!!!!!!!!

Pour plus de détails sur la connexion du jeu de réplication PrinergyDB, reportez-vous au Guide d'installation EPM (Emergency Platemaking) et Hot Standby avec Double-Take pour Prinergy 9.x
Remarque : Après avoir terminé la mise à niveau de tous les serveurs, un test de basculement doit être réalisé pour s'assurer que la prise en charge de Hot Standby fonctionne correctement.

Sv translation
languageit

Per Prinergy 9.5 è disponibile un aggiornamento alla versione Double-Take 8.4. Contattare l'ufficio del supporto locale e fare riferimento alla domanda ID 75659 della knowledge base per l'installazione.

Double-Take 8.2 dovrebbe supportare Prinergy 9.5, tuttavia la versione 8.4 è quella ufficialmente qualificata. L'aggiornamento di DT 8.4 risolve il problema descritto nella sezione della risposta con ID 75473, quindi si consiglia di effettuare l'aggiornamento il prima possibile.

Prima di effettuare l'aggiornamento, è necessario assicurarsi di avere diritto a una nuova licenza Double-Take 8.4. Contattare l'ufficio del supporto locale con il numero di serie Double-Take 8.2 e Prinergy per verificare la propria idoneità.

Quando si esegue l'aggiornamento del server primario su un sistema operativo Windows 2016/2019 con Double-Take 8.2/8.4, eseguire le operazioni elencate nell'ordine specificato.

Nota: è possibile eseguire i passaggi riportati di seguito quando si effettua l'aggiornamento a Prinergy 9.5 e successivamente si effettua l'aggiornamento a Double-Take 8.4

  1. Disconnettere il set di repliche Prinergy DB sul server primario:
    1. Aprire Double-Take Console: Accedere a Avvia > Tutte le applicazioni > Double-Take Console o fare doppio clic su Console UI.exe in C:\Program Files\Vision Solutions\Double-Take\Console.
    2. Registrare le licenze.
    3. Nel menu Vai, selezionare Gestione processi.
    4. Fare clic con il pulsante destro del mouse sul processo PrinergyDb e selezionare Interrompi.
  2. Eseguire l'aggiornamento del server primario.
  3. Eseguire l'aggiornamento del server (di failover) secondario.
  4. Riconnettere il processo di replica PrinergyDB:
    1. Sul server primario, aprire Double-Take Console: Accedere a Avvia > Tutte le applicazioni > Double-Take Console o fare doppio clic su Console UI.exe in C:\Program Files\Vision Solutions\Double-Take\Console.
    2. Nel menu Vai, selezionare Gestione processi.
    3. Fare clic con il pulsante destro del mouse su ciascuno dei processi , PrinergyDB e PrinergyDBRestore, quindi procedere con l'eliminazione.
    4. Aprire la Guida all'installazione di DT

...

    1. : https://resources.kodak.com/services/132b351/en_US/software_solutions/workflow_software/prinergy/docs/version95/EPM_and_Hot_Standby_with_Double-Take_for_Prinergy_9.5_Installation_Guide_2022.pdf

    ...

        1. Nota: la guida all'installazione di DT è disponibile solo per il personale Kodak. Contattare l'ufficio del supporto locale.
      1. Pagina 14 o sotto l'intestazione: Creazione di un set di replica del database Oracle, creazione di nuovi processi
      2. Configurare entrambi i processi , PrinergyDB e PrinergyDBRestore. Implementare le istruzioni in fondo a pagina 16 o sotto l'intestazione: Configurare la replica del database

    ...

      1. in Double-Take Console

    ...

      1. - Mirror, Verify & Orphaned File/Path Mapping)

    ...

      1. Fare clic su OK per salvare

    Promemoria importante: non avviare PrinergyDBRestore!!!!!!!!!

    ...

    Per istruzioni più dettagliate sulla connessione del processo di replica PrinergyDB, consultare la Guida all'installazione di EPM (Emergency Platemaking) e Hot Standby con Double-Take per Prinergy 9.x
    Nota:. dopo aver completato l'aggiornamento di tutti i server, è necessario eseguire un test di failover per assicurarsi che il supporto Hot Standby funzioni correttamente.

    Sv translation
    languageja

    Prinergy 9.5 で利用可能な Double-Take 8.4 へのアップデートがあります。お近くのサポートオフィスにお問い合わせの上、ナレッジベースのアンサー ID 75659 を参照してインストールしてください。

    Double-Take 8.2 は Prinergy 9.5 で引き続き動作しますが、8.4 が正式認定バージョンです。DT 8.4 アップデートは、アンサー ID 75473 に記載されている問題を修正するため、できるだけ早くアップデートすることをお勧めします。

    更新する前に、新しい Double-Take 8.4 ライセンスの資格があることを確認する必要があります。Double-Take 8.2 と Prinergy のシリアル番号を添えて、地域のサポート担当者にお問い合わせください。サポート担当者がお客様の資格を確認します。

    Double-Take 8.2/8.4 が導入されている Windows 2016/2019 オペレーティング システムで実行されているプライマリ サーバーをアップグレードする場合は、以下の操作を指定された順序で実行します。

    Prinergy 9.5 にアップグレードしてから Double-Take 8.4 以降にアップグレードする場合は、以下の手順を実行できる点に注意してください。

    1. プライマリ サーバーの PrinergyDB 複製ジョブの接続を解除します。
      1. Double-Take Console を開きます。[スタート]>[すべてのプログラム]>[Double-Take Console]を選択するか、C:\Program Files\Vision Solutions\Double-Take\Console の Console UI.exe をダブルクリックします。
      2. ライセンスを記録します。
      3. [Go(移動)]メニューから、[Manage Jobs(ジョブの管理)]を選択します。
      4. PrinergyDb]ジョブを右クリックして、[停止]を選択します。
    2. プライマリ サーバーをアップグレードします。
    3. セカンダリ(フェイルオーバー)サーバーをアップグレードします。
    4. PrinergyDB replication ジョブを再接続します。
      1. プライマリ サーバーで、Double-Take Console を開きます。[スタート]>[すべてのプログラム]>[Double-Take Console]を選択するか、C:\Program Files\Vision Solutions\Double-Take\Console の Console UI.exe をダブルクリックします。
      2. [Go(移動)]メニューから、[Manage Jobs(ジョブの管理)]を選択します。
      3. 各ジョブ([PrinergyDB]および[PrinergyDBRestore])を右クリックして削除します。
      4. DT インストールガイド https://resources.kodak.com/services/132b351/en_US/software_solutions/workflow_software/prinergy/docs/version95/EPM_and_Hot_Standby_with_Double-Take_for_Prinergy_9.5_Installation_Guide_2022.pdf を開きます。
        1. 注意:DT インストールガイドはコダックの担当者のみに利用できます。お住まいの地域のサポートオフィスにお問い合わせください。
      5. 14 ページまたはヘッダー:[Oracle データベース Replication Set の作成]の下で新規ジョブを作成する
      6. ジョブ PrinergyDB および PrinergyDBRestore を両方とも設定します。16 ページの下部または以下のヘッダーの下で指示内容を実行します。Double-Take Console でのデータベース複製の設定 – ミラー、検証、孤立ファイル/パス マッピング
      7. OK]をクリックして保存します。

    重要な注意事項: PrinergyDBRestore を絶対に起動しないでください!

    PrinergyDB 複製ジョブの接続手順の詳細については、『EPM(Emergency Platemaking)and Hot Standby with Double-Take for Prinergy 9.x Installation Guide』(Prinergy 9.x 対応 EPM および Hot Standby/Double-Take インストール ガイド)を参照してください。
    注意:すべてのサーバーのアップグレードを完了したら、フェイルオーバー テストを実行して、Hot Standby のサポートが正しく機能していることを確認する必要があります。

    Sv translation
    languagezh

    有可用于印能捷 9.5 的 Double-take 8.4 更新。请联系您的区域支持办公室并参考知识库答案 ID 75659 进行安装。

    Double-take 8.2 应该能够继续支持印能捷 9.5,但 8.4 是官方认可的版本。DT 8.4 更新修复了答案 ID 75473 中描述的问题,因此建议尽快更新。

    在更新之前,您需要确保自己有资格获得新的 Double-Take 8.4 许可证。请联系您的区域支持办公室并提供您的 Double-Take 8.2 和印能捷序列号,他们将确认您的资格。

    升级在 Windows 2016/2019 操作系统 (Double-Take 8.2/8.4) 上运行的主服务器时,请按指定的顺序执行列出的任务。

    请注意,您可以在升级到印能捷 9.5 时执行以下步骤,然后再升级 double-take 8.4

    1. 断开主服务器上的印能捷数据库复制作业。
      1. 打开 Double-Take 控制台:转到 开始 > 所有运行程序 > Double-Take 控制台,或双击 C:\Program Files\Vision Solutions\Double-Take\Console 中的 Console UI.exe。
      2. 记录许可证。
      3. 转至菜单中,选择管理作业
      4. 右键单击印能捷数据库作业,然后选择停止
    2. 升级主服务器。
    3. 升级二级(故障转移)服务器。
    4. 重新连接印能捷数据库复制作业:
      1. 在主服务器上,打开 Double-Take 控制台:转到 开始 > 所有运行程序 > Double-Take 控制台,或双击 C:\Program Files\Vision Solutions\Double-Take\Console 中的 Console UI.exe。
      2. 转至菜单中,选择管理作业
      3. 右键单击每个作业(印能捷数据库PrinergyDBRestore),然后删除。
      4. 打开 DT 安装指南:https://resources.kodak.com/services/132b351/en_US/software_solutions/workflow_software/prinergy/downloads/version95/EPM_and_Hot_Standby_with_Double-Take_for_Prinergy_9.5_Installation_Guide_2022.pdf
        1. 注意:DT 安装指南仅供 Kodak 人员使用,请致电您的区域支持办公室。
      5. 遵循第 14 页或以下标题进行操作:创建 Oracle 数据库复制设置、创建新作业
      6. 配置作业:印能捷数据库PrinergyDBRestore。实施第 16 页底部的说明或遵循以下标题进行操作:在 Double-Take 控制台中配置数据库复制 - 镜像、验证和孤立文件/路径映射
      7. 单击确定以保存

    重要提醒:请勿启动 PrinergyDBRestore!!!

    有关连接印能捷数据库复制作业的更多详细说明,请参阅 EPM(紧急制版)和具有 Double-Take for Prinergy 9.x 的热备份安装指南
    注意:完成所有服务器升级后,必须完成故障转移测试以确保热备份支持正常工作。