Begin the migration process by migrating a few process templates that use Harmony curves. For initial testing, save a copy of a commonly used output process template and migrate it. Follow the steps below for each process template.

  1. In Workshop's Process Template Editor:
    1. Open the process template for editing.
    2. Open the Calibration and Screening panel.
    3. Record the Harmony Print Curve and Plate Curve names.
    4. Leave the process template open for step 3.
  2. In ColorFlow:
    1. Import the print curve and select Show in Prinergy Print Curves. See Importing a Harmony print calibration curve.
    2. Import the plate curve and select Show in Prinergy Plate Curves. See Importing a Harmony plate calibration curve.
  3. In Process Template Editor:
    1. Open the Calibration and Screening panel.
    2. Select Curve Source: ColorFlow Current State.
      The
      Print Curve and Plate Curve selections remain the same, except that %% NONE %% is replaced by None.
      Note: If either curve selection changes from a named Harmony curve to None, the Harmony curve name could not be found in ColorFlow. Close the process template without saving and repeat the process. 
    3. Save and close the process template.