- In the Print Curves tab, under Calibration Curves, click the Add button .
- Add the print device and drag it to the viewer window.
- Click the Properties icon and define the device condition properties.
- Create a measurement chart and measure device output samples:- Click the Measurement icon .
- Perform one of the following actions:- If you already have a P2P25, P2P51, or other measurement data file for your print device, you can import it.
- Measure a built-in P2P or P2P51 chart.
 
 
- Define the G7 calibration:- Click the Calibration icon .
- If you do not want the curve to be visible in Prinergy, clear the Show in Prinergy check box. This is selected automatically for new curves.
- Click the Process Inks tab and select G7.
- Click OK.
 
Note: If the calibrated output device condition has extended process inks, they are calibrated to linear Spot Color Tone Value (SCTV) response.



