Note: Either while the Device Curves Edit dialog is open, or after it has been closed, you can select Undo or Redo from the Edit menu (or use Ctrl/Cmd-Z or Ctrl/Cmd-Y).
- In the Print Curves tab, under Calibration Curves, click the Add button .
- Add the print device and drag it to the viewer window.
- Click the Properties icon and define the device condition properties.
- Create a measurement chart and measure device output samples:
- Click the Measurement icon .
- Do one of the following actions:
- If you already have the measurement data file for your print device, you can import it.
- If you only want to generate a tonal match curve, create a tint ramp chart and measure it.
- If you want to generate gray balance curves, measure a built-in P2P25 or P2P51 chart.
- When you launch a measurement or import operation, in the Print Characterization Curve dialog, select the curve that you used in Prinergy when you output the test chart.
This is typically Linear, but may be a cutback curve for high-gain printing, or a bump curve for flexographic printing.
Select the print curve target and define calibration:
- Click the Calibration icon .
- If you do not want the curve to be visible in Prinergy, clear the Show in Prinergy check box. This is selected automatically for new curves.
Click the Process Inks tab and select the desired target device condition from the Target dropdown list.
ColorFlow provides a list of built-in industry CMYK specifications that you can use as your target response. If you can't find the desired target from the list, you can create a custom CMYK Reference device condition as your target.
If you selected the G7 check box, the G7 target is automatically selected and the Target list is not available for selecting an alternate target.- If you have added and measured one or more spot inks, in the Spot Inks tab, select a target from the Target list and select a curve method, as follows:
- If you have measured the SCTV response of spot inks, select Target: Linear (selected automatically). This sets the Curve Method to Linear SCTV.
- To calibrate spot inks to an EDA or TVI target, select any Target value other than Linear or None. This sets the Curve Method to Tonal Match.
- To generate linear curves that can be manually adjusted, select Target value None. This sets the Curve Method to Manual Adjustments Only.
- Note: For a spot ink whose response has not been measured, the following settings always apply: Target: None and Curves Method: Manual Adjustments Only. You can view the Curve Method for each spot ink by clicking Details... in the Calibration definition dialog.
- Click OK.
Notes:
- If the calibrated output device condition has extended process inks, they are calibrated to match the Spot Color Tone Value (SCTV) response of same-named inks present in the selected target. For extended process inks not present in the target, linear SCTV calibration is performed.s
- When you create a print calibration curve, the output device condition also appears as an SCO in a color setup whose PCO is the simulation target device condition. The curve can be selected in Prinergy by either its curve name, or by the color setup and output device condition.