Page tree

  1. In the Print Curves tab, under Calibration Curves, click the Add button .
  2. Add the print device and drag it to the viewer window. 
  3. Click the Properties icon  and define the device condition properties.
  4. Create a measurement chart and measure device output samples:
    1. Click the Measurement icon .
    2. Perform one of the following actions:
  5. Define the G7 calibration:
    1. Click the Calibration icon .
    2. If you do not want the curve to be visible in Prinergy, clear the Show in Prinergy check box. This is selected automatically for new curves.
    3. Click the Process Inks tab and select G7.
    4. Click OK.

NoteIf the calibrated output device condition has extended process inks, they are calibrated to linear Spot Color Tone Value (SCTV) response.