Email address field character limitation

User email address and Secure Link email address fields are limited to 80 and 90 characters respectively.

The PressProof client will need to be updated manually if SSL is in use

The PressProof client will not detect that a software update is available if SSL is in use. To update the PressProof client, on your Mac, you will need to mount the Installer share from your InSite Prepress Portal server and install the PressProof client.

Downloading multiple files

When downloading multiple files, a compressed single (.zip) file is created, so that only a single file is transferred at a time. If the multiple files were transferred separately, the user would have to click OK (or otherwise acknowledge or allow the transfer) for each individual file. This might not be an issue if only two or three files are being downloaded, but for dozens or hundreds of pages at a time it is highly undesirable behavior. This behavior of the download process is due to internet security procedures and protocols. If you cannot extract the *.zip file with the OS embedded unzip tool, use a third-party tool, such as iZip (Mac) and 7-zip (Windows).

Bypass Login does not support certain characters in passwords

Bypass Login functionality does not support the use of special characters in user passwords. The unsupported characters include < >.

For passwords, the following characters are supported: ~!@#$%^&*()_+{}|:?;,./-=[]\

For usernames when using Bypass Login, this restriction does not exist and all of the following characters are supported: ~!@#$%^&*()_+{}|:?;,./-=[]\< >

Upload and download does not support certain characters in file names

HTML5 uploads/downloads do not support the use of special characters in the file names. These characters include (but are not limited to): / \ * | ? < > ,

Note: If these characters appear in the filename, an error message is displayed and the upload will not proceed.

Upload and download fails with long file names

For uploads, the overall maximum file name length is determined by the system’s maximum allowed file path length of 259 characters, comprised of the Prinergy Server Name, Job Share Name, Job Name, and other names.

For downloads, the maximum file path length is 122 out of 259 characters including the file name. To minimize any upload or download issues, short file names should be used.

Upload Processing Rules using Prinergy Workflow Templates no longer supported

Prinergy Workflow Templates can no longer be selected for Upload Processing Rules. Customers who upgraded from InSite Prepress Portal version 8.x will no longer see their Upload Processing Rules. As a workaround, use RBA to manage jobs through the Prinergy/InSite workflow; or, use a Copy rule instead of a Refine rule, copying to a Prinergy Hot Folder that uses the Workflow Template.

Limiting access to certain color targets or setting a default target for color customers is not supported in InSite Prepress Portal 9.x

When you create or edit a customer and you have the appropriate user rights, you can select the Use Matchprint Virtual option, but you cannot limit the color targets for use by a customer or set a default target.
This option will not be supported until a future release.

Separations viewed in PressProof will render using D50 light source only

If you use the GTI or JNL light source for viewing color accurate surfaces, when you turn separations off and click Apply, only the D50 light source is used to render in Separations view. When you turn on all the separations again and want to review color accurately, you will need to return to Window mode and select Regenerate View. If you use the GTI or JNL light source, this will render the surface again using the correct light source.

Light source will be displayed as none in PressProof client for LPV jobs

If you are viewing surfaces of LPV jobs, while the designated light source that you have configured will be applied for color accurate viewing, in window mode, it will show the light source as none.

Error layer not viewable in Smart Review for LPV jobs

If error layers are created in a Prinergy LPV job, the error layer is currently not displayed as a separate layer in Smart Review or Pressproof. Review your LPV jobs carefully in Prinergy to make sure nothing is on the error layer. (INST-13623)

Page aliases in Prinergy are not compatible with InSite Smart Review and PressProof

If page aliases are created in a Prinergy job, the alias cannot currently be displayed in Smart Review or Pressproof. They will appear as grey boxes. (INST-13530)

Login to IPP Enterprise satellites on iPad application is not supported

If you use the iPad application with IPP Enterprise, you must use the URL of the Enterprise to log in and access jobs.

"Remember me on this computer" checkbox only remembers the user name

Due to the security enhancements in InSite Prepress Portal 9.x, "Remember me on this computer" checkbox on the login page only remembers the user name.

Greek translations are no longer available 

Greek translations are no longer available in the UI, but e-mails will still be displayed in Greek if user selects Greek for e-mail.

Safari uses significant amount of memory for high-definition monitors

Safari may show a warning message - "This website is using significant memory. Closing it may improve the responsiveness of your Mac." when you continuously open heavy-contents pages in Smart Review with a high-definition monitor. You may need to (repeatedly) close and re-launch Safari.

PressProof

Client: M1 chipset not supported

is not supported in the KMS environment

As hosting equipment 'in the cloud' becomes more prevalent, Kodak must specify requirements for our products that guaratee a minimum base of customer satisaction and user experience. At the current time, using a PressProof server hosted in the KMS environment is not supported.

In the meantime, customers in KMS are advised to have an on-prem PressProof standalone server, with the files hosted on-prem (preferably on the PressProof standalone server).

Note that PressProof standalone only supports the TIFF workflow, meaning that only 4 colour TIFF files can be used (spot colors will be converted)Mac computers with the M1 chipset do not support the PressProof client application at this time.

Sv translation
languagede

Begrenzung der Zeichenanzahl im E-Mail-Adressfeld

Die Felder für die E-Mail-Adresse des Benutzers und die E-Mail-Adresse des Secure Link sind auf 80 bzw. 90 Zeichen begrenzt.

Der PressProof-Client muss manuell aktualisiert werden, wenn SSL verwendet wird

Der PressProof-Client wird nicht erkennen, dass ein Software-Update verfügbar ist, wenn SSL verwendet wird. Um den PressProof-Client auf Ihrem Mac zu aktualisieren, müssen Sie die Installer-Freigabe von Ihrem InSite Prepress Portal-Server mounten und den PressProof-Client installieren.

Herunterladen von mehreren Dateien

Beim Herunterladen mehrerer Dateien wird eine einzelne komprimierte (.zip) Datei erstellt, so dass immer nur eine einzige Datei übertragen wird. Würden mehrere Dateien separat übertragen, müsste der Benutzer für jede einzelne Datei auf OK klicken (oder die Übertragung anderweitig bestätigen oder erlauben). Dies mag kein Problem sein, wenn nur zwei oder drei Dateien heruntergeladen werden, aber bei Dutzenden oder Hunderten von Seiten ist dies ein höchst unerwünschtes Verhalten. Dieses Verhalten des Download-Prozesses ist auf Internet-Sicherheitsverfahren und -protokolle zurückzuführen. Wenn Sie die *.zip-Datei nicht mit dem in das Betriebssystem integrierten Entpackungsprogramm extrahieren können, verwenden Sie ein Programm eines Drittanbieters, z. B. iZip (Mac) und 7-zip (Windows).

Bypass Login unterstützt bestimmte Zeichen in Passwörtern nicht

Die Funktion zur Umgehung der Anmeldung unterstützt die Verwendung von Sonderzeichen in Benutzerpasswörtern nicht. Zu den nicht unterstützten Zeichen gehört < >.

Für Passwörter werden die folgenden Zeichen unterstützt: ~!@#$%^&*()_+{}|:?;,./-=[]\

Für Benutzernamen bei der Verwendung von Bypass Login gibt es diese Einschränkung nicht und alle folgenden Zeichen werden unterstützt: ~!@#$%^&*()_+{}|:?;,./-=[]\< >

Upload und Download unterstützen bestimmte Zeichen in Dateinamen nicht

HTML5-Uploads/Downloads unterstützen die Verwendung von Sonderzeichen in den Dateinamen nicht. Diese Zeichen umfassen (sind aber nicht beschränkt auf): / \ * | ? < > ,

Hinweis: Wenn diese Zeichen im Dateinamen vorkommen, wird eine Fehlermeldung angezeigt und der Upload wird nicht fortgesetzt.

Upload und Download schlägt bei langen Dateinamen fehl

Beim Upload wird die maximale Länge des Dateinamens durch die maximal zulässige Dateipfadlänge von 259 Zeichen bestimmt, die sich aus dem Prinergy-Servernamen, dem Job-Share-Namen, dem Jobnamen und anderen Namen zusammensetzt.

Für Downloads beträgt die maximale Dateipfadlänge 122 von 259 Zeichen einschließlich des Dateinamens. Um Probleme beim Hoch- oder Herunterladen zu minimieren, sollten kurze Dateinamen verwendet werden.

Die Einschränkung des Zugriffs auf bestimmte Farbziele oder die Festlegung eines Standardziels für Farbkunden wird in InSite Prepress Portal 9.x nicht unterstützt

Wenn Sie einen Kunden anlegen oder bearbeiten und über die entsprechenden Benutzerrechte verfügen, können Sie die Option Matchprint virtuell verwenden auswählen, aber Sie können die Farbziele für die Verwendung durch einen Kunden nicht einschränken oder ein Standardziel festlegen.
Diese Option wird erst in einer zukünftigen Version unterstützt.

Separationen, die in PressProof angezeigt werden, werden nur mit der Lichtquelle D50 gerendert

Wenn Sie die GTI- oder JNL-Lichtquelle für die Anzeige farbgenauer Oberflächen verwenden, wird in der Separationsansicht nur die D50-Lichtquelle zum Rendern verwendet, wenn Sie Separationen ausschalten und auf Übernehmen klicken. Wenn Sie alle Separationen wieder einschalten und die Farbgenauigkeit überprüfen möchten, müssen Sie in den Fenstermodus zurückkehren und Ansicht neu generieren wählen. Wenn Sie die GTI- oder JNL-Lichtquelle verwenden, wird die Oberfläche erneut mit der richtigen Lichtquelle gerendert.

Die Lichtquelle wird im PressProof-Client für LPV-Aufträge als "keine" angezeigt

Wenn Sie Oberflächen von LPV-Aufträgen betrachten, wird die von Ihnen konfigurierte Lichtquelle zwar für eine farbgetreue Darstellung verwendet, im Fenstermodus wird die Lichtquelle jedoch als "keine" angezeigt.

Fehlerebene kann in Smart Review für LPV-Aufträge nicht angezeigt werden

Wenn in einem Prinergy-LPV-Auftrag Fehlerebenen erstellt werden, wird die Fehlerebene derzeit nicht als separate Ebene in Smart Review oder Pressproof angezeigt. Überprüfen Sie Ihre LPV-Aufträge in Prinergy sorgfältig, um sicherzustellen, dass sich nichts auf der Fehlerebene befindet. (INST-13623)

Login zu IPP Enterprise-Satelliten auf iPad-Anwendung wird nicht unterstützt

Wenn Sie die iPad-Anwendung mit IPP Enterprise verwenden, müssen Sie die URL von Enterprise verwenden, um sich anzumelden und auf Aufträge zuzugreifen.

Das Kontrollkästchen "Remember me on this computer" speichert nur den Benutzernamen

Aufgrund der Sicherheitsverbesserungen in InSite Prepress Portal 9.x wird in der Checkbox "Remember me on this computer" auf der Anmeldeseite nur noch der Benutzername gespeichert.

Griechische Übersetzungen sind nicht mehr verfügbar 

Griechische Übersetzungen sind in der Benutzeroberfläche nicht mehr verfügbar, aber E-Mails werden weiterhin auf Griechisch angezeigt, wenn der Benutzer Griechisch für E-Mails auswählt.

Safari verbraucht bei hochauflösenden Monitoren sehr viel Speicher

Safari zeigt möglicherweise eine Warnmeldung an: "Diese Website verbraucht viel Speicherplatz. Das Schließen dieser Website kann die Reaktionsfähigkeit Ihres Macs verbessern.", wenn Sie in Smart Review mit einem hochauflösenden Monitor kontinuierlich Seiten mit umfangreichen Inhalten öffnen. Möglicherweise müssen Sie Safari (wiederholt) schließen und neu starten.

PressProof-Client: M1-Chipsatz wird nicht unterstützt

Mac-Computer mit dem M1-Chipsatz unterstützen die PressProof-Client-Anwendung zur Zeit nicht.

...