Sample printlink configuration file

################################
  • PrintLink Configuration File #
  • (Created February 2005) #
    Sv translation
    languageen

    Use this feature to customize the internal CIP3 tags in the PrintLink PPF file. The CIP3 and CIP4 PPF file specification establishes an open standard for exchanging information among print production devices from multiple vendors, including platesetters, and presses.

    Anchor
    Bookmark536_concept3591__section_AE4EDA9Bookmark536_concept3591__section_AE4EDA9
    Anchor
    Bookmark536_concept3591__table_E0EFF5A43Bookmark536_concept3591__table_E0EFF5A43
    Code Block
    ################################
    # PrintLink Configuration File #
    # (Created February 2005) #
    ################################
    #Custom template for /CIP3AdmJobName #AdmJobName=%job% #Custom Template for /CIP3AdmSheetName 
    #Custom template for /CIP3AdmJobName #AdmJobName=%job% #Custom Template for /CIP3AdmSheetName
    #AdmSheetName=%signature%/%sheet%%side% #Custom template for /PageSection (only written
    for
    GenericNewspaper
     for
            GenericNewspaper #PageSection=%signatureletter%

    
    
    #Less common settings - these override the settings in the press interface

    
    
    #ReplaceUnderscoresFromJobName=false #RotateWithPreviewMatrix=false #OutputJDF=false #UseImpoNameForAdmJobName=true #UseSigNumInSheetNum=false #UseImpoNameInFilename=true

    
            #OutputLowPageNumber=false

     

    In Prinergy Evo software, there are three standard tags:

    • AdmJobName
    • AdmSheetName
    • PageSection AnchorBookmark536_concept3591__ul_32228291ED95Bookmark536_concept3591__ul_32228291ED95 AnchorBookmark536_concept3591__li_CAE32609161FBookmark536_concept3591__li_CAE32609161FAdmJobName AnchorBookmark536_concept3591__li_98C7461EBB86Bookmark536_concept3591__li_98C7461EBB86AdmSheetName AnchorBookmark536_concept3591__li_B6A4F9E8DC62Bookmark536_concept3591__li_B6A4F9E8DC62PageSection-this is specific to newspapers. PageSection is only populated if you enable it in the sample file and select Generic Newspaper Press Interface from the Press Interface list in the PrintLink section of the process template.

    With the tags, you can now use custom naming variables, such as Sheet or Job, for the internal CIP tags. All of the Prinergy Evo variables that work for external naming will now work for the CIP tags. For a listing of the custom naming variables, see Tell me more about custom file naming.
    AnchorBookmark536_concept3591__section_C0D3C6EBookmark536_concept3591__section_C0D3C6Efile naming.

    Changing default press interface settings

    You can edit the PrintLink configuration file to override the following press interface defaults. You activate the tag by removing the crosshatch (#) and then changing the default value (for example, from =false to =true).
    #AdmInkColors=true (option to add spot colors in L*A*B. This is useful for Brisque customers who are migrating to Prinergy and use Heidelberg Reader Stations.)
    #AlwaysFront=true (option to output backs to fronts.)
    #SwapFrontswithBacks=true (to output so that back data appears before front data)
    #ReplaceUnderscoresFromJobName=false
    #RotateWithPreviewMatrix=false
    #OutputJDF=false
    #OutputLowPageNumber=false
    #UseImpoNameForAdmJobName=true
    #UseSigNumInSheetNum=false
    #UseImpoNameInFilename=true
    anchor

    Bookmark536_concept3591__section_BE5E000Bookmark536_concept3591__section_BE5E000Example of how to use tags and variables

    For the AdmnJobName=%job% tag, if your Prinergy Evo job name is Docket12345 then the resulting CIP tag will look like AdmJobName (Docket 12345).
    To configure the PrintLink file:

    AnchorBookmark536_concept3591__ol_C6459F564952Bookmark536_concept3591__ol_C6459F564952 AnchorBookmark536_concept3591__li_84B0ADFB9F71Bookmark536_concept3591__li_84B0ADFB9F71

    PrintLink file:

    1. Open the sample config file, found at
      <your Prinergy Evo server name>\PgyEvoConfig\PrintLink\ .anchor
    2. Bookmark536_concept3591__li_C496E8AC8A26Bookmark536_concept3591__li_C496E8AC8A26Edit the tags and variables that you require. AnchorBookmark536_concept3591__li_4FAD73D16396Bookmark536_concept3591__li_4FAD73D16396
    3. Copy the sample file to a location you can browse to from a process template. You may want to create a folder inside
      <your Prinergy Evo server name>\PgyEvoConfig. AnchorBookmark536_concept3591__li_AD731D03847A
      <your Prinergy Evo server name>\PgyEvoConfig.Bookmark536_concept3591__li_AD731D03847A
    4. In your process template, in the PrintLink section, click Browse beside the Press Interface Configuration File box and navigate to the folder and file you created.

    You can continue to choose your existing press interface from the Press Interface list in the PrintLink section and the enabled tags in the sample PPF file will override the interface defaults.

    Bookmark531_concept3591__section_AE4EDA9
    Exemple de fichier de configuration PrintLink

    ################################
  • PrintLink Configuration File #
  • (Created February 2005) #
    Sv translation
    languagefr

    Utilisez cette fonction pour personnaliser les balises CIP3 internes dans le fichier PPF PrintLink. La spécification des fichiers PPF CIP3 et CIP4 établit un standard ouvert pour l'échange d'informations entre les systèmes de production de plusieurs fournisseurs, notamment entre les insoleuses de plaques et les presses.

    Anchor
    Bookmark531_concept3591__section_AE4EDA9
    Anchor
    Bookmark531_concept3591__table_E0EFF5A43Bookmark531_concept3591__table_E0EFF5A43
    Code Block
    ################################
    # PrintLink Configuration File #
    # (Created February 2005) #
    ################################
    #Custom template for /CIP3AdmJobName #AdmJobName=%job% #Custom Template for /CIP3AdmSheetName 
    #Custom template for /CIP3AdmJobName #AdmJobName=%job% #Custom Template for /CIP3AdmSheetName
    #AdmSheetName=%signature%/%sheet%%side% #Custom template for /PageSection (only written
    for
    GenericNewspaper
     for
            GenericNewspaper #PageSection=%signatureletter%

    
    
    #Less common settings - these override the settings in the press interface

    
    
    #ReplaceUnderscoresFromJobName=false #RotateWithPreviewMatrix=false #OutputJDF=false #UseImpoNameForAdmJobName=true #UseSigNumInSheetNum=false #UseImpoNameInFilename=
    true
    true
            #OutputLowPageNumber=false

    Il existe trois balises standard dans le logiciel Prinergy Evo :

     Il existe trois balises standard dans le logiciel Prinergy Evo :

    • AdmJobName
    • AdmSheetName AnchorBookmark531_concept3591__ul_32228291ED95Bookmark531_concept3591__ul_32228291ED95 AnchorBookmark531_concept3591__li_CAE32609161FBookmark531_concept3591__li_CAE32609161FAdmJobName AnchorBookmark531_concept3591__li_98C7461EBB86Bookmark531_concept3591__li_98C7461EBB86AdmSheetName AnchorBookmark531_concept3591__li_B6A4F9E8DC62Bookmark531_concept3591__li_B6A4F9E8DC62
    • PageSection : spécifique aux journaux. PageSection est remplie uniquement si vous l'activez dans le fichier d'exemple et sélectionnez Interface journal générique dans la liste Interface de la presse dans la section PrintLink du modèle de processus.
    Bookmark531_concept3591__ol_C6459F564952 AnchorBookmark531_concept3591__li_84B0ADFB9F71Bookmark531_concept3591__li_84B0ADFB9F71

    Avec les balises, vous pouvez désormais utiliser des variables de dénomination personnalisées, par exemple Feuille ou Travail, pour les balises CIP internes. Toutes les variables Prinergy Evo qui fonctionnent avec une dénomination externe peuvent maintenant utiliser les balises CIP. Pour obtenir la liste des variables de dénomination personnalisées, consultez la section Plus d'informations sur la dénomination de fichier personnalisée.
    Anchor Tell me more about custom file naming.Bookmark531_concept3591__section_C0D3C6EBookmark531_concept3591__section_C0D3C6E
    Modification des paramètres par défaut de l'interface de la presse
    Vous pouvez modifier le fichier de configuration PrintLink pour remplacer les valeurs par défaut de l'interface de la presse suivantes. Activez la balise en supprimant le signe dièse (#) pour modifier la valeur par défaut (par exemple, de =faux à =vrai).
    #AdmInkColors=vrai (option permettant d'ajouter des couleurs d'accompagnement dans L*A*B. Elle est utile pour les utilisateurs Brisque qui migrent vers Prinergy et utilisent des Stations de lecture Heidelberg.)
    #AlwaysFront=true (option pour sortir les recto en verso.)
    #SwapFrontswithBacks=true (pour la sortie de telle sorte que les données de l'arrière apparaissent devant les données de l'avant)
    #ReplaceUnderscoresFromJobName=false
    #RotateWithPreviewMatrix=false
    #OutputJDF=false
    #OutputLowPageNumber=false
    #UseImpoNameForAdmJobName=true
    #UseSigNumInSheetNum=false
    #UseImpoNameInFilename=true
    AnchorBookmark531_concept3591__section_BE5E000Bookmark531_concept3591__section_BE5E000Exemple d'utilisation des balises et des variables
    Pour la balise AdmnJobName=%job%, si votre nom de travail Prinergy Evo est Docket12345, la balise CIP sera AdmJobName (Docket 12345).
    Pour configurer le fichier PrintLink :

    AnchorBookmark531_concept3591__ol_C6459F564952

    AdmJobName (Docket 12345).
    Pour configurer le fichier PrintLink :

    1. Ouvrez le fichier de configuration fourni en exemple qui se situe à l'emplacement
      <votre nom de serveur Prinergy Evo>\PgyEvoConfig\PrintLink\. AnchorBookmark531_concept3591__li_C496E8AC8A26Bookmark531_concept3591__li_C496E8AC8A26Modifiez les balises et les variables à votre guise. AnchorBookmark531_concept3591__li_4FAD73D16396Bookmark531_concept3591__li_4FAD73D16396
    2. Modifiez les balises et les variables à votre guise.
    3. Copiez le fichier d'exemple à un emplacement accessible à partir d'un modèle de processus. Vous pouvez créer un dossier dans
      <votre nom de serveur Prinergy Evo>\PgyEvoConfig. AnchorBookmark531_concept3591__li_AD731D03847ABookmark531_concept3591__li_AD731D03847A
    4. Dans votre modèle de processus, dans la section PrintLink, cliquez sur Parcourir à côté du champ Fichier de configuration de l'interface d'impression et naviguez jusqu'au dossier et au fichier créé.

    Vous pouvez continuer de choisir votre interface de presse existante dans la liste Interface de la presse de la section PrintLink et les balises activées dans le fichier d'exemple PPF écrasent les valeurs par défaut de l'interface.

    PrintLink 配置文件样本

    ################################
  • PrintLink Configuration File #
  • (Created February 2005) #

    PrintLink 配置文件样本

    Sv translation
    languagezh

    使用此功能在 PrintLink PPF 文件中自定义内部 CIP3 标记。CIP3 和 CIP4 PPF 文件规格要求为多家供应商印刷生产设备(包括印版记录机和印刷机)间的信息交换确立了一个公开的标准。

    Anchor
    Bookmark536_concept3591__section_AE4EDA9Bookmark536_concept3591__section_AE4EDA9
    Anchor
    Bookmark536_concept3591__table_E0EFF5A43Bookmark536_concept3591__table_E0EFF5A43
    Code Block
    ################################
    # PrintLink Configuration File #
    # (Created February 2005) #
    ################################
    #Custom template for /CIP3AdmJobName #AdmJobName=%job% #Custom Template for /CIP3AdmSheetName 
    #Custom template for /CIP3AdmJobName #AdmJobName=%job% #Custom Template for /CIP3AdmSheetName
    #AdmSheetName=%signature%/%sheet%%side% #Custom template for /PageSection (only written
    for
    GenericNewspaper
     for
            GenericNewspaper #PageSection=%signatureletter%

    
    
    #Less common settings - these override the settings in the press interface

    
    
    #ReplaceUnderscoresFromJobName=false #RotateWithPreviewMatrix=false #OutputJDF=false #UseImpoNameForAdmJobName=true #UseSigNumInSheetNum=false #UseImpoNameInFilename=true

    #OutputLowPageNumber=false
    
            #OutputLowPageNumber=false

    印能捷演化版软件中有三种标准标记:

    印能捷演化版软件中有三种标准标记:

    • AdmJobName
    • AdmSheetName
    • AnchorBookmark536_concept3591__ul_32228291ED95Bookmark536_concept3591__ul_32228291ED95 AnchorBookmark536_concept3591__li_CAE32609161FBookmark536_concept3591__li_CAE32609161FAdmJobName AnchorBookmark536_concept3591__li_98C7461EBB86Bookmark536_concept3591__li_98C7461EBB86AdmSheetName AnchorBookmark536_concept3591__li_B6A4F9E8DC62Bookmark536_concept3591__li_B6A4F9E8DC62PageSection - 这特定于报纸。仅当在样本文件中启用了 PageSection,并从处理模板的 PrintLink 部分的印刷机接口列表选择常规报纸印刷接口,才会填充 PageSection。

    使用这些标记,现在可以为内部 CIP 标记使用自定义命名变量,例如印张和作业。所有用于外部命名的印能捷演化版变量现在将用于 CIP 标记。有关自定义命名变量的列表,请参见更多自定义文件名称的信息
    AnchorBookmark536_concept3591__section_C0D3C6ETell me more about custom file namingBookmark536_concept3591__section_C0D3C6E
    更改默认印刷机接口设置
    可以编辑 PrintLink 配置文件以覆盖以下印刷机接口默认值。您可以通过删除井号 (#) 并更改默认值(例如将 =false 更改为 =true)激活标记。
    #AdmInkColors=true(在 L*A*B 中添加专色的选项。这对于从必胜迁移到印能捷且使用 Heidelberg Reader Station 的用户很有用。)
    #AlwaysFront=true(将反面输出到正面的选项。)
    #SwapFrontswithBacks=true(输出时背面数据显示在正面数据之前)
    #ReplaceUnderscoresFromJobName=false
    #RotateWithPreviewMatrix=false
    #OutputJDF=false
    #OutputLowPageNumber=false
    #UseImpoNameForAdmJobName=true
    #UseSigNumInSheetNum=false
    #UseImpoNameInFilename=true
    anchor
    Bookmark536_concept3591__section_BE5E000Bookmark536_concept3591__section_BE5E000使用标记和变量的示例
    对于 AdmnJobName=%job% 标记,如果印能捷演化版的作业名为 Docket12345,则最终 CIP 标记将显示为 AdmJobName (Docket 12345)
    配置 PrintLink 文件:

    AnchorBookmark536_concept3591__ol_C6459F564952


    配置 PrintLink 文件:

    Bookmark536_concept3591__ol_C6459F564952 AnchorBookmark536_concept3591__li_84B0ADFB9F71Bookmark536_concept3591__li_84B0ADFB9F71

    1. 打开样本配置文件,它位于 \\<印能捷演化版服务器名称>\PgyEvoConfig\PrintLink\。
    2. AnchorBookmark536_concept3591__li_C496E8AC8A26Bookmark536_concept3591__li_C496E8AC8A26根据需要编辑标记和变量。 AnchorBookmark536_concept3591__li_4FAD73D16396Bookmark536_concept3591__li_4FAD73D16396将样本文件复制到可从处理模板浏览到的位置。您可能想在 \\<印能捷演化版服务器名称>\PgyEvoConfig 中创建文件夹。 AnchorBookmark536_concept3591__li_AD731D03847ABookmark536_concept3591__li_AD731D03847A
    3. 将样本文件复制到可从处理模板浏览到的位置。您可能想在 \\<印能捷演化版服务器名称>\PgyEvoConfig 中创建文件夹。
    4. 在处理模板的 PrintLink 部分,单击印刷机接口配置文件框旁的浏览,然后浏览至您所创建的文件夹和文件。

    还可以继续从 PrintLink 部分中的印刷机接口列表和将忽略接口默认值的样本 PPF 文件中启用的标记中选择现有印刷机接口。

    Bookmark437_concept3591__section_AE4EDA9
    PrintLink-Beispielkonfigurationsdatei

    ################################
  • PrintLink Configuration File #
  • (Created February 2005) #
    Sv translation
    languagede

    Verwenden Sie diese Option, um die internen CIP3-Tags in einer PrintLink PPF-Datei anzupassen. Die CIP3 und CIP4 PPF-Dateispezifikation bilden einen offenen Standard für den Austausch von Informationen zwischen Druckproduktionsgeräten (z. B. Plattenbelichtern und Druckmaschinen) verschiedener Anbieter.

    Anchor
    Bookmark437_concept3591__section_AE4EDA9
    Anchor
    Bookmark437_concept3591__table_E0EFF5A43Bookmark437_concept3591__table_E0EFF5A43
    Code Block
    ################################
    # PrintLink Configuration File #
    # (Created February 2005) #
    ################################
    #Custom template for /CIP3AdmJobName #AdmJobName=%job% #Custom Template for /CIP3AdmSheetName 
    #Custom template for /CIP3AdmJobName #AdmJobName=%job% #Custom Template for /CIP3AdmSheetName
    #AdmSheetName=%signature%/%sheet%%side% #Custom template for /PageSection (only written
    for
    GenericNewspaper
     for
            GenericNewspaper #PageSection=%signatureletter%

    
    
    #Less common settings - these override the settings in the press interface

    
    
    #ReplaceUnderscoresFromJobName=false #RotateWithPreviewMatrix=false #OutputJDF=false #UseImpoNameForAdmJobName=true #UseSigNumInSheetNum=false #UseImpoNameInFilename=
    true
    true
            #OutputLowPageNumber=false

    Es gibt drei Standardtags in der Prinergy Evo-Software:gibt drei Standardtags in der Prinergy Evo-Software:

    • AdmJobName
    • AdmSheetName AnchorBookmark437_concept3591__ul_32228291ED95Bookmark437_concept3591__ul_32228291ED95 AnchorBookmark437_concept3591__li_CAE32609161FBookmark437_concept3591__li_CAE32609161FAdmJobName AnchorBookmark437_concept3591__li_98C7461EBB86Bookmark437_concept3591__li_98C7461EBB86AdmSheetName AnchorBookmark437_concept3591__li_B6A4F9E8DC62Bookmark437_concept3591__li_B6A4F9E8DC62
    • PageSection – Dies ist spezifisch für Zeitungen. PageSection wird nur ausgefüllt, wenn Sie es in der Beispieldatei aktivieren und die Option Generische Schnittstelle für Zeitungsdruckmaschinen in der Liste Druck-Interface im Abschnitt PrintLink der Prozessvorlage auswählen.

    Mit den Tags können Sie jetzt benutzerdefiniert benannte Variablen für die internen CIP-Tags verwenden wie „Bogen" oder „Job". Alle Prinergy Evo-Variablen, die für die externe Benennung funktionieren, können jetzt auch für CIP-Tags verwendet werden. Eine Liste der Variablen für die benutzerdefinierte Benennung finden Sie unter Einzelheiten zur benutzerdefinierten Dateibenennung.
    AnchorBookmark437_concept3591__section_C0D3C6E Tell me more about custom file naming.Bookmark437_concept3591__section_C0D3C6E
    Ändern der Standardeinstellungen für das Druck-Interface
    Sie können die PrintLink-Konfigurationsdatei bearbeiten, um die folgenden Druck-Interface-Standardeinstellungen zu überschreiben. Sie aktivieren das Tag, indem Sie die Kreuzschraffur (#) entfernen und anschließend den Standardwert ändern (z. B. von =false in =true).
    #AdmInkColors=true (Option zum Hinzufügen von Sonderfarben in L*A*B. Dies ist vor allem für Brisque-Kunden hilfreich, die zu Prinergy migrieren und Heidelberg Reader Stations verwenden.)
    #AlwaysFront=true (Option zum Drucken von der Rückseite zur Vorderseite)
    #SwapFrontswithBacks=true (Option zum Drucken der Daten auf der Rückseite vor den Daten der Vorderseite)
    #ReplaceUnderscoresFromJobName=false
    #RotateWithPreviewMatrix=false
    #OutputJDF=false
    #OutputLowPageNumber=false
    #UseImpoNameForAdmJobName=true
    #UseSigNumInSheetNum=false
    #UseImpoNameInFilename=true
    anchor
    Bookmark437_concept3591__section_BE5E000Bookmark437_concept3591__section_BE5E000Beispiel zum Verwenden von Tags und Variablen
    Wenn der Prinergy Evo-Jobname für das Tag AdmnJobName=%job% „Docket12345" lautet, ergibt sich daraus das CIP-Tag AdmJobName (Docket 12345).
    So konfigurieren Sie die PrintLink-Datei:

    AnchorBookmark437_concept3591__ol_C6459F564952Bookmark437_concept3591__ol_C6459F564952 AnchorBookmark437_concept3591__li_84B0ADFB9F71Bookmark437_concept3591__li_84B0ADFB9F71

    -Datei:

    1. Öffnen Sie die Datei „sample config", die sich unter
      <Name des Prinergy Evo-Servers>\PgyEvoConfig\PrintLink\ befindet.anchor
    2. Bookmark437_concept3591__li_C496E8AC8A26Bookmark437_concept3591__li_C496E8AC8A26Bearbeiten Sie die erforderlichen Tags und Variablen. AnchorBookmark437_concept3591__li_4FAD73D16396Bookmark437_concept3591__li_4FAD73D16396
    3. Kopieren Sie die Beispieldatei an einen Speicherort, an den Sie aus einer Prozessvorlage heraus navigieren können. Sie können auch einen Ordner innerhalb von
      <Name des Prinergy Evo-Servers>\PgyEvoConfig erstellen. AnchorBookmark437_concept3591__li_AD731D03847ABookmark437_concept3591__li_AD731D03847APrinergy Evo-Servers>\PgyEvoConfig erstellen.
    4. Klicken Sie in der Prozessvorlage im Abschnitt PrintLink auf Durchsuchen neben dem Feld Konfigurationsdatei für Druck-Interface, und navigieren Sie zum Ordner und zu der Datei, die Sie erstellt haben.

    Sie können weiterhin Ihre vorhandene Druck-Interface aus der Liste Druck-Interface im Abschnitt PrintLink auswählen, woraufhin die aktivierten Tags in der PPF-Beispieldatei die Interface-Standardwerte außer Kraft setzen.

    Bookmark520_concept3591__section_AE4EDA9
    File di configurazione PrintLink di esempio

    ################################
  • PrintLink Configuration File #
  • (Created February 2005) #
    Sv translation
    languageit

    Utilizzare questa funzione per personalizzare i tag CIP3 interni del file PPF PrintLink. La specifica dei file PPF delle iniziative CIP3 e CIP4 ha stabilito uno standard aperto per lo scambio di informazioni tra dispositivi di stampa di produttori diversi, inclusi i platesetter e le macchine da stampa.

    Anchor
    Bookmark520_concept3591__section_AE4EDA9
    Anchor
    Bookmark520_concept3591__table_E0EFF5A43Bookmark520_concept3591__table_E0EFF5A43
    Code Block
    ################################
    # PrintLink Configuration File #
    # (Created February 2005) #
    ################################
    #Custom template for /CIP3AdmJobName #AdmJobName=%job% #Custom Template for /CIP3AdmSheetName 
    #Custom template for /CIP3AdmJobName #AdmJobName=%job% #Custom Template for /CIP3AdmSheetName
    #AdmSheetName=%signature%/%sheet%%side% #Custom template for /PageSection (only written
    for
    GenericNewspaper
     for
            GenericNewspaper #PageSection=%signatureletter%

    
    
    #Less common settings - these override the settings in the press interface

    
    
    #ReplaceUnderscoresFromJobName=false #RotateWithPreviewMatrix=false #OutputJDF=false #UseImpoNameForAdmJobName=true #UseSigNumInSheetNum=false
    #UseImpoNameInFilename=true
     #UseImpoNameInFilename=true
            #OutputLowPageNumber=false

    I tag standard del software Prinergy Pro sono tre:standard del software Prinergy Pro sono tre:

    • AdmJobName
    • AdmSheetName AnchorBookmark520_concept3591__ul_32228291ED95Bookmark520_concept3591__ul_32228291ED95 AnchorBookmark520_concept3591__li_CAE32609161FBookmark520_concept3591__li_CAE32609161FAdmJobName AnchorBookmark520_concept3591__li_98C7461EBB86Bookmark520_concept3591__li_98C7461EBB86AdmSheetName AnchorBookmark520_concept3591__li_B6A4F9E8DC62Bookmark520_concept3591__li_B6A4F9E8DC62
    • PageSection - specifico per i quotidiani. PageSection viene popolato solo se il tag è attivato nel file di esempio e si seleziona Interfaccia stampa quotidiani generica dall'elenco Interfaccia stampa nella sezione PrintLink del process template.

    Con i tag, è ora possibile utilizzare le variabili di denominazione personalizzate, ad esempio Foglio o Lavoro, per i tag CIP interni. Tutte le variabili Prinergy Evo che funzionano per la denominazione esterna funzioneranno ora per i tag CIP. Per un elenco delle variabili di denominazione personalizzate, vedere Ulteriori informazioni sulla denominazione file personalizzata.
    AnchorBookmark520_concept3591__section_C0D3C6E Tell me more about custom file naming.Bookmark520_concept3591__section_C0D3C6E
    Modifica delle impostazioni dell'interfaccia di stampa predefinite
    È possibile modificare il file di configurazione PrintLink per sostituire le impostazioni predefinite dell'interfaccia di stampa seguenti. Attivare il tag rimuovendo il simbolo (#) e modificando il valore predefinito (per esempio, from =false to =true).
    #AdmInkColors=true (opzione per aggiungere tinte piatte in L*A*B, utile per i clienti Brisque che migrano a Prinergy ed utilizzano le stazioni di lettura Heidelberg).
    #AlwaysFront=true (opzione per l'output di pagine retro in pagine fronte).
    #SwapFrontswithBacks=true (per l'output in modo che i dati delle pagine retro siano visualizzati prima dei dati delle pagine fronte)
    #ReplaceUnderscoresFromJobName=false
    #RotateWithPreviewMatrix=false
    #OutputJDF=false
    #OutputLowPageNumber=false
    #UseImpoNameForAdmJobName=true
    #UseSigNumInSheetNum=false
    #UseImpoNameInFilename=true
    anchor
    Bookmark520_concept3591__section_BE5E000Bookmark520_concept3591__section_BE5E000Esempio sull'uso di tag e variabili
    Per il tag AdmnJobName=%job%, se il nome lavoro Prinergy Evo è Docket12345, il tag CIP risultante apparirà come AdmJobName (Docket 12345).
    Per configurare il file PrintLink:

    AnchorBookmark520_concept3591__ol_C6459F564952Bookmark520_concept3591__ol_C6459F564952 AnchorBookmark520_concept3591__li_84B0ADFB9F71Bookmark520_concept3591__li_84B0ADFB9F71

    file PrintLink:

    1. Aprire il file di configurazione di esempio situato in
      <nome del server Prinergy Evo in uso>\PgyEvoConfig\PrintLink\ .anchor
    2. Bookmark520_concept3591__li_C496E8AC8A26Bookmark520_concept3591__li_C496E8AC8A26Modificare i tag e le variabili in base alle proprie esigenze. AnchorBookmark520_concept3591__li_4FAD73D16396Bookmark520_concept3591__li_4FAD73D16396
    3. Copiare il file di esempio in una posizione cui è possibile accedere da un process template. In alcuni casi può essere opportuno creare una cartella in
      <nome del server Prinergy Evo in uso>\PgyEvoConfig. AnchorBookmark520_concept3591__li_AD731D03847ABookmark520_concept3591__li_AD731D03847Aserver Prinergy Evo in uso>\PgyEvoConfig.
    4. Nel process template in uso, all'interno della sezione PrintLink, fare clic su Sfoglia accanto alla casella File di configurazione dell'interfaccia di stampa e selezionare la cartella e il file creati.

    È possibile continuare a selezionare l'interfaccia di stampa esistente in uso dall'elenco Interfaccia stampa nella sezione PrintLink. I tag attivati nel file di esempio PPF assumono la priorità rispetto alle impostazioni predefinite dell'interfaccia.

    Bookmark535_concept3591__section_AE4EDA9
    Archivo de configuración de PrintLink de muestra

    ################################
  • PrintLink Configuration File #
  • (Created February 2005) #
    Sv translation
    languagees

    Utilice esta opción para personalizar las etiquetas CIP3 internas del archivo PPF PrintLink. Las especificaciones CIP3 y CIP4 PPF establecen un estándar abierto para el intercambio de información entre dispositivos de producción de impresión de diversos proveedores, incluidas las filmadoras de planchas y las prensas.

    Anchor
    Bookmark535_concept3591__section_AE4EDA9
    Anchor
    Bookmark535_concept3591__table_E0EFF5A43Bookmark535_concept3591__table_E0EFF5A43
    Code Block
    ################################
    # PrintLink Configuration File #
    # (Created February 2005) #
    ################################
    #Custom template for /CIP3AdmJobName #AdmJobName=%job% #Custom Template for /CIP3AdmSheetName 
    #Custom template for /CIP3AdmJobName #AdmJobName=%job% #Custom Template for /CIP3AdmSheetName
    #AdmSheetName=%signature%/%sheet%%side% #Custom template for /PageSection (only written
    for
    GenericNewspaper
     for
            GenericNewspaper #PageSection=%signatureletter%

    
    
    #Less common settings - these override the settings in the press interface

    
    
    #ReplaceUnderscoresFromJobName=false #RotateWithPreviewMatrix=false #OutputJDF=false #UseImpoNameForAdmJobName=true #UseSigNumInSheetNum=false #UseImpoNameInFilename=true

    #OutputLowPageNumber=false
    
            #OutputLowPageNumber=false

     En Prinergy Evo hay tres etiquetas estándar:

    • AdmJobName
    • AdmSheetName

    En Prinergy Evo hay tres etiquetas estándar:

    • AnchorBookmark535_concept3591__ul_32228291ED95Bookmark535_concept3591__ul_32228291ED95 AnchorBookmark535_concept3591__li_CAE32609161FBookmark535_concept3591__li_CAE32609161FAdmJobName AnchorBookmark535_concept3591__li_98C7461EBB86Bookmark535_concept3591__li_98C7461EBB86AdmSheetName AnchorBookmark535_concept3591__li_B6A4F9E8DC62Bookmark535_concept3591__li_B6A4F9E8DC62
    • PageSection: esto es específico para los periódicos. PageSection sólo se rellena si lo activa en el archivo de ejemplo y selecciona Interfaz de prensa periodística genérica de la lista Interfaz de prensa de la sección PrintLink de la plantilla de proceso.

    Con las etiquetas, puede ahora utilizar variables de nomenclatura personalizadas (p. ej., hoja o trabajo) para las etiquetas CIP internas. Todas las variables de Prinergy Evo que funcionan con la nomenclatura externa también lo harán con las etiquetas CIP. Para obtener una lista de las variables de nomenclatura personalizadas, consulte Más información sobre los nombres de archivos personalizados.
    AnchorBookmark535_concept3591__section_C0D3C6E Tell me more about custom file naming.Bookmark535_concept3591__section_C0D3C6E
    Cambio de los valores predeterminados de interfaz de prensa
    Puede editar el archivo de configuración de PrintLink para que anule los valores predeterminados de interfaz de prensa que aparecen a continuación. La etiqueta se activa mediante la eliminación de la almohadilla (#) y el cambio del valor predeterminado (por ejemplo, de =false a =true).
    #AdmInkColors=true (Opción para añadir colores planos en L*A*B. Esto resulta útil para los clientes de Brisque que van a cambiar a Prinergy y utilizan Heidelberg Reader Stations).
    #AlwaysFront=true (Opción para generar salida de reversos en anversos).
    #SwapFrontswithBacks=true (Para generar salidas de forma que los datos del reverso aparezcan antes que los datos del anverso)
    #ReplaceUnderscoresFromJobName=false
    #RotateWithPreviewMatrix=false
    #OutputJDF=false
    #OutputLowPageNumber=false
    #UseImpoNameForAdmJobName=true
    #UseSigNumInSheetNum=false
    #UseImpoNameInFilename=true
    anchor
    Bookmark535_concept3591__section_BE5E000Bookmark535_concept3591__section_BE5E000Ejemplo de cómo usar las etiquetas y las variables
    En cuanto a la etiqueta AdmnJobName=%job%, si el nombre de trabajo de Prinergy Evo es Docket12345, la etiqueta CIP resultante tendrá un aspecto parecido a AdmJobName (Docket 12345).
    Para configurar el archivo PrintLink:

    AnchorBookmark535_concept3591__ol_C6459F564952Bookmark535_concept3591__ol_C6459F564952 AnchorBookmark535_concept3591__li_84B0ADFB9F71Bookmark535_concept3591__li_84B0ADFB9F71

    archivo PrintLink:

    1. Abra el archivo de configuración de ejemplo, ubicado en
      <nombre del servidor Prinergy Evo>\PgyEvoConfig\PrintLink\.anchor
    2. Bookmark535_concept3591__li_C496E8AC8A26Bookmark535_concept3591__li_C496E8AC8A26Edite las etiquetas y las variables que necesite. AnchorBookmark535_concept3591__li_4FAD73D16396Bookmark535_concept3591__li_4FAD73D16396
    3. Copie el archivo de ejemplo en una ubicación a la que se pueda acceder desde una plantilla de proceso. Quizá podría crear una carpeta en
      <nombre de su servidor Prinergy Evo >\PgyEvoConfig. AnchorBookmark535_concept3591__li_AD731D03847ABookmark535_concept3591__li_AD731D03847A
    4. En la plantilla de proceso, en la sección PrintLink, haga clic en Examinar junto al cuadro Archivo de configuración de la interfaz de prensa y vaya hasta la carpeta y archivo que ha creado.

    Puede seguir seleccionando la interfaz de prensa existente de la lista Interfaz de prensa de la sección PrintLink, y las etiquetas activadas en el archivo de ejemplo "sample_PPF.txt" anularán los valores predeterminados de la interfaz.