Note: The "Gamut Check" step will be skipped when running an inline spectrophotometer in Automated mode. When using the inline spectrophotometer, keep it in Manual mode until after the "Gamut Check" step.
The purpose of this step is to check the color measurements for the gamut of Media Configuration components so far, such as: media, printer resolution, spectrophotometer measurement condition, usage, and Total Ink Limit value.
Note that the "Gamut Check" step will be skipped when running an inline spectrophotometer in Automated mode.
The software uses the measurements from the Single Channel Ink Limit chart to compute initial gamut statistics. It compares the results to historical data for each Usage Type, and computes a "PASS" or "Warning" answer. A pass indicates that initial data looks good for this media configuration, so it is recommended to continue. If a "Warning" is computed, it is recommended to take a few minutes to make sure you have selected the right components in this media configuration. see questions "Troubleshooting a Gamut WARNING message" section below. You can always choose to continue, no matter what the gamut results are.
...
estSpotGVolumeDiff = estimated Gamut Volume Difference from a Spot Color Gamut Volume.
Media Configuration fails for Gamut Tests:
(1) high minimum L* - the minimum L* value of your Media Configuration is too high. High values can result in spectrophotometer measurement failures, or inadequate contrast in output images.
(2) poor paper white - the media/paper color measurement (CIE L*a*b*) is too far from the color measurement of the Target Profile. A color simulation cannot be accurate enough if the color of the paper is too far from your Target Profile.
(3) low gamut volume - the estimated Gamut Volume is too small compared to your Target Profile, with the selected usage.
...
Target Profile Results: (PminL*: 8.06), (pMYC*: 83.9), (pCYC*: 72.84), (pCMC*: 49.25), (Pmaxa*: 74.12), (Pmaxb*: 93.16), (Pmina*: -68.42), (Pminb*: -46.15), (estProfGamutVolumeDiff: 1019469), (estSpotGVolumeDiff: 147626)
This Media Configuration looks good so far! Note that some color standards require the paper measurement value to be within 1.5 CIE dE00, whereas this only checks that the value is within 3.0 dEab. You might want to check the paper color difference value in the dialog in this situation.
Example of Information displayed with a "Warning" (you must scroll down to see all of the information):
...
Target Profile Results: (PminL*: 9.05), (pMYC*: 83.23), (pCYC*: 70.93), (pCMC*: 50.18), (Pmaxa*: 75.0), (Pmaxb*: 92.99), (Pmina*: -66.0), (Pminb*: -46.02), (estProfGamutVolumeDiff: 1060811), (estSpotGVolumeDiff: 147626)
This Media Configuration failed for its measured Paper white Value. The paper color measurement was too far from the Target Profile. This can be corrected by choosing a different media, spectrophotometer measurement condition, or in some cases by printing an ink tint value on the output (usually only a Yellow ink tint value is considered visually acceptable).
Troubleshooting a Gamut WARNING message:
...