Page tree

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published by Scroll Versions from space KPS and version 11.0

...

  • Supported Epson Stylus Pro Series and SureColor PSeries printer and inline spectrophotometer equipped with either the SpectroProofer ILS (with UV-cut filter or unfiltered) or ILS30 (Mx) head

Terminology note: Unless otherwise specified, the term inline spectrophotomoter spectrophotometer refers to the first-generation ILS (ILS20) and the second-generation ILS30. Important: Replacing an ILS with an ILS30 also requires a printer firmware upgrade.

...

  • The terms i1, i1Pro, i1Pro 2, i1Pro 3 and Eye-One are generally interchangeable.
  • The term i1iO includes the inserted i1 and can mean either a first-  second- third generation (“2” and "3") model.
  • The term offline distinguishes portable spectrophotometers from inline spectrophotometers installed in some proofers.

Spectrophotometers for the Epson WT7900 printer and white ink

To avoid damaging white ink on proofs, use only a spectrophotometer supported for use with the Epson Stylus Pro WT7900 printer and white ink.

...

Supported devices

...

Devices not supported

●     X-Rite i1Pro 2, and i1Pro 3

●     X-Rite i1iO2, and i1iO3 automated scanning table

...

●     Inline SpectroProofer (ILS, ILS30)

●     X-Rite i1iSis and i1iSis XL automated chart readers

●     X-Rite DTP 70

Note: When you use the Epson Stylus Pro WT7900 without white ink, you can use any of the spectrophotometers supported for Matchprint Inkjet printers.

Be extra careful when you measure white ink printed by surface mode on media. In this case you measure the ink on media, and it is easy to scratch the white ink with the spectrophotometer.

...

  • .

...

Spectrophotometer combinations in selection lists

...

M0M1M2
i1Pro 2 and i1Pro 3i1Pro 2 and i1Pro 3i1Pro 2 and i1Pro 3
i1iO 2 and i1iO 3i1iO 2 and i1iO 3i1iO 2 and i1iO 3
Inline ILS30Inline ILS30Inline ILS30
Inline ILS20 U
Not supported on newer PSeries printers

Inline ILS20 UV
Not supported on newer PSeries printers
i1iO U
i1iO UV
iSis 1.0 
iSis 1.0
iSisXL 1.0
iSisXL 1.0
Eye-One U
Eye-One UV
i1Pro U
i1Pro UV

DTP70 U
Untested and not recommended. 
Although listed, we no longer have
this type of spectro for testing.


DTP70 UV
Untested and not recommended. 
Although listed, we no longer have
this type of spectro for testing.

SpectroScan
Although this instrument is still listed in the 
media configuration, serial communication
is not really supported on newer PCs.