Note |
---|
Instructions are included for Prinergy, InSite Prepress Portal (IPP), and Insite Creative Workflow (ICW). |
Obtaining SentinelOne Endpoint Protection software
Kodak products support the unmanaged version of SentinelOne Endpoint Protection. From the following page, log into your SentinelOne account.
...
For assistance with obtaining an unmanaged client installer and performing the installation, contact SentinelOne.
Configuring the SentinelOne File Exclusions
It is very important that the file scanning exclusions are set properly. Failing to do so will result in poor performance, processing errors and possible downtime.
...
Note |
---|
Each section includes a list of folders to exclude. This is the easiest way to exclude the Kodak workflow software. Alternatively, you can exclude specific files within those folders. This is slightly more secure but is error-prone and must be very carefully entered. |
Prinergy Server Path Exclusions
General Paths to Exclude (easiest):
On all Prinergy servers (Primary and Secondary):
...
User Library > Application Support > Kodak
IPP Path Exclusions
General Paths to Exclude (easiest):
Code Block |
---|
C:\Creo C:\Oracle C:\Program Files (x86) J:\Inetpub J:\InSiteFileTransfer J:\InSiteNotification J:\InSiteReports J:\Jobs (if used) |
...
Please disable SentinelOne during IPP software upgrades. Failing to do this will cause the upgrade to take much longer.
ICW Path Exclusions
General Paths to Exclude (easiest):
Code Block |
---|
C:\Creo C:\Oracle C:\Program Files (x86) J:\Inetpub J:\InSiteArchival J:\InSiteExport J:\InSiteFileTransfer J:\InSiteImport J:\Libraries J:\Orant J:\Projects J:\TWArchMon J:\TWFonts J:\TWSystemData C:\OracleClient C:\Orant |
...