Limitations that are new to Prinergy 9.0.2:

IMPORTANT NOTE:

Customers who use Preps Page and Page Bleed marks, should consider NOT upgrading to Prinergy 9.0.2 / Preps 9.0.3 at this time, without first understanding the risks - eg: possibility of plate spoilage.

...

  • In order for Device Track to operate correctly within Internet Explorer 11, the setting Display intranet sites in Compatibility View must be disabled. This setting is enabled by default.
    To change the Compatibility View setting, in Internet Explorer, from the Tools menu, select Compatibility View Settings, and in the Compatibility View Settings dialog box, clear the Display intranet sites in Compatibility View check box, and click Close to apply the change. [PRINERGY-41259]
  • In Internet Explorer 11, when you use the Refresh button in the browser to refresh Device Track, sometimes the data displayed is the data saved in its cache and not the data from the server.
  • When using Internet Explorer with Device Track, Device Track requires version 11 or later. [PRINERGY-41757]

  • Resizing columns in Device Track may result in columns being pushed off screen. [PRINERGY-41180]
  • An issue with status reporting coming from Kodak Xpo can cause the In Process queues in Prinergy’s Device Track UI and Xpo to get out of sync and display output separation in the wrong order in Device Track. [PRINERGY-47843]

  • After successful completion of output to EFI or Canon digital front-ends, the completed output jobs are absent from all queues in Device Track. [PRINERGY-47923] [PRINERGY-43780]

  • In some older versions of EFI Fiery software, the number of inks reported was limited to five. This would cause jobs with more than five colors to incorrectly limit their color reporting back to Prinergy’s Device Track UI to five colors. [PRINERGY-46698]
  • When resubmitting a separation via Device Track, the separation receives a new Job ID from the device control software (Xpo or Print Console). This is due to the separation being treated as a new output instance rather than a remake of a previous output.

  • Incomplete Notification Messages on Prinergy 9.0 Track with Print Console 5.16 [PRINERGY-52855]
  • Device messages prompt on Print Console 5.24 do not pop up on Prinergy 9.0.2 TRACK > Device Messages Window [PRINERGY-52855]