estSpotGVolumeDiff = estimated Gamut Volume Difference from a Spot Color Gamut Volume.
Media Configuration fails for Gamut Tests:
(1) high minimum L* - the minimum L* value of your Media Configuration is too high. High values can result in spectrophotometer measurement failures, or inadequate contrast in output images.
...
Target Profile Results: (PminL*: 9.05), (pMYC*: 83.23), (pCYC*: 70.93), (pCMC*: 50.18), (Pmaxa*: 75.0), (Pmaxb*: 92.99), (Pmina*: -66.0), (Pminb*: -46.02), (estProfGamutVolumeDiff: 1060811), (estSpotGVolumeDiff: 147626)
This Media Configuration failed for its measured Paper white Value. The paper color measurement was too far from the Target Profile. This can be corrected by choosing a different media, spectrophotometer measurement condition, or in some cases by printing an ink Tint value on the output (usually only a Yellow ink tint value is considered visually acceptable).
Troubleshooting a Gamut WARNING message:
...