Bookmark535_concept2877__table_DD211C782

Sv translation
languageen

Prinergy Evo software uses Common Density Limit to prevent traps where they are not needed. For example, a gap will not be visible due to the darkness or density at that place. Common density is a neutral density calculated from the common parts of each single separation. In the table below, C60 M25 Y30 K10 and C40 M31 Y40 K14 have the common parts of C40 M25 Y30 K10. Spot colors are also considered, if present. Therefore, the common density is a value for the darkness for the worst possible misregistration. If this common density is above the Common Density Limit setting, no traps are required.

Separation

Anchor
Bookmark535_concept2877__table_0A6DD6ECFBookmark535_concept2877__table_0A6DD6ECF

Color1

Color2

Relative Ink Dot percentage

Step limit (25%) satisfied?

Cyan

60%

40%

(60-40)/40 = 0.5 or 50%

Yes, 50% >25%

Magenta

25%

31%

(31-25)/25 = 0.24 or 24%

No, 24% < 25%

Yellow

30%

40%

(40-30)/30 = 0.33 or 33%

Yes, 33% > 25%

Key

10%

14%

 

Ignored, doesn't meet 5% minimum difference

For the example above (common parts of C40 M25 Y30 K10), the common density is calculated as follows (CD = common density, ND = neutral density):

Anchor
Bookmark535_concept2877__table_DD211C782

CD

= ND[Cyan]

+ ND[Magenta]

+ND[Yellow]

+ND[Key]

 

= 0.19

+0.13

+0.05

+0.07

 

= 0.44

 

 

 

0.44

< 0.5

 

 

 

The common density of the two example colors is lower than the default limit of 0.5, so a trap would be created.