Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The Prinergy Evo Client software must have Transmission Control Protocol (TCP) and User Datagram Protocol (UDP) access to the server. The Prinergy Evo Client software requires two TCP ports and one UDP port to be used in tunnel mode. For example, the Prinergy Evo Client software can connect to a server over a Point-to-Point Tunneling Protocol (PPTP) or virtual private network (VPN) connection that is not filtering traffic. The port numbers Prinergy Evo uses for client connections are:

 

Sv translation
languageen
Bookmark17_concept2376__table_EDA200F80ABookmark17_concept2376__table_EDA200F80A
Anchor

Service

Protocol

Port Number

Client XML RPC

TCP

290001 (default)

Client Notification

TCP

Variable (default)

Client Locator

UDP

50007

 

The two TCP ports can be reconfigured to always

"float"

“float” (that is, their actual port number is decided when the Prinergy Evo system starts) or to be a fixed value. By default, the XML RPC service port number is hard-wired to 290001 but the Client Notification service port number

"floats"

“floats”.

The Client Locator service cannot be changed.

To change the port numbers for the two TCP ports, edit the configuration file in your Prinergy Evo server installation directory using the path:

<your server's hard drive>\Program Files (x86)\Kodak\Prinergy Evo <version number>\config_data\System\UIServer-Local\config.txt

You can use a text editor to modify this file.

Important: Make a copy of the original file before you start modifying it.

Look for the lines in the configuration file:

Prinergy.JUIS.XmlRpcServicePort=29001

Prinergy.JUIS.RemoteMonitorServicePort=0

Any item set to 0 will

"float

“float.

"

Otherwise, the system uses the port number you suggest. If that port is already in use by another process then the server will fail to start, so be careful with your choice of hard-wired port numbers. Once you edit the configuration file, restart the Prinergy Evo Server software. If you run into problems, use the original copy of theconfig.txtfile and restart.

Note: The software firewall that ships with Windows Server 2008 is not supported on a Prinergy Evo server. Activating the built-in Windows firewall will cause unpredictable system behavior. Any firewalling requirements must be met with an external device. Choices include a hardware firewall, software firewall running on another (non-workflow) server, or a firewall appliance in a virtual environment. Placement of the firewall in your network infrastructure is important, as Prinergy Evo requires specific ports to be opened between the Evo server and client workstations. Information about the firewall requirements of InSite Prepress Portal, InSite Creative Workflow and other Kodak portal products can be found in the respective products' documentation.

 

Sv translation
languagefr

Le logiciel Prinergy Evo Client doit avoir accès aux protocoles TCP et UDP sur le serveur. Le logiciel Prinergy Evo Client nécessite deux ports TCP et un port UDP à utiliser en mode tunnel. Par exemple, le logiciel Prinergy Evo Client peut établir une connexion avec un serveur sur un protocole PPTP ou un réseau privé virtuel ne filtrant pas le trafic. Prinergy Evo utilise les numéros de ports suivants pour les connexions clients :

Anchor
Bookmark17_concept2376__table_EDA200F80A
Bookmark17_concept2376__table_EDA200F80A
Service

Protocole

Numéro de port

Client XML RPC

TCP

290001 (paramètre par défaut)

Notification client

TCP

Variable (valeur par défaut)

Localisateur de client

UDP

50007

Les deux ports TCP peuvent être configurés de manière à être toujours « flottants » (c'est-à-dire que leur numéro de port réel est déterminé au démarrage de Prinergy Evo) ou à être une valeur fixe. Par défaut, le numéro de port de service XML RPC est fixé sur 290001 mais le numéro de port de service de notification client est toujours « flottant ».
Il est impossible de modifier le service de localisation de client.
Pour modifier les numéros de port des deux ports TCP, modifiez le fichier de configuration dans le répertoire d'installation du serveur Prinergy Evo à l'aide du chemin :
<disque dur du serveur>\Program Files\Kodak\Prinergy Evo <numéro de version>\config_data\System\UIServer-Local\config.txt
Vous pouvez utiliser un éditeur de texte pour modifier ce fichier.
Important : réalisez une copie de l'original du fichier avant de commencer à le modifier.
Examinez les lignes suivantes dans le fichier de configuration :
Prinergy.JUIS.XmlRpcServicePort=29001
Prinergy.JUIS.RemoteMonitorServicePort=0
Tout élément défini sur 0 sera « flottant ». Sinon, le système utilise le numéro de port que vous spécifiez. Si ce port est déjà utilisé par un autre processus, le serveur ne peut pas démarrer ; choisissez donc précautionneusement vos numéros de ports fixes. Lorsque vous modifiez le fichier de configuration, redémarrez le logiciel Prinergy Evo Server. Si vous rencontrez des problèmes, utilisez l'original du fichier config.txt et redémarrez.

...