Prerequisites:

You should receive an installation key and the location of the Cloud Agent installer from your Kodak service representative.

Download and install the Prinergy Cloud update on his Prinergy server on premise (Can be downloaded from https://services.kodak.com/app/answers/detail/a_id/72886, see the Installing the Prinergy Cloud Archiving update.

Technical requirements

  • Prinergy Workflow 7.5.0, 7.5.1, 8.0.2, 8.1.1, 8.1.2, 8.2.0
  • Internet connection:
    • Min: 50/50 Mbs
    • Recommended: 100/100 Mbs

Installing the Prinergy Cloud Services update on the customer site

Note: This procedure should be performed by the customer user on the Prinergy server on site. The rest of the procedures are performed by Kodak support personnel.

Note: When you run the Prinergy Cloud Agent update installer on the Prinergy server, the update will replace some of the files on the Prinergy server.

Fresh installation on a primary server (First time installation of Kodak Cloud Services)

  1. In UADM, stop the Prinergy server if it is running.
  2. Close the UADM application.
  3. From the downloaded Prinergy Cloud update Zip file, open the CloudAgentSetup folder, and run the latest CloudServicesSetup_X.XBLD<xxx>.exe file
  4. In the Welcome page that appears, enter the installation key that you received by the Kodak support personnel.



  5. Click Next.
  6. The cloud Agent installer displays your supported services.



  7. Click Install.
    When the installation process is complete, The following message is dispalyed:



  8. In UADM, start the Prinergy server.
  9. To verify that the Prinergy Cloud Archiving update is installed:
    1. On the Prinergy server, start the Administration software (UADM).
    2. From the Help menu, select About.
    3. Make sure that Cloud Services Version :1.<x>.<x> appears. If this text string does not appear, the Prinergy Cloud Archiving update is not installed. For more information, see ‎the Updating Prinergy Cloud Archiving Service on the customer site section.



      Note: The build number 1.1_<xxx> in the image should match the build number in the setup exe name.

Installing the Prinergy Cloud update on a secondary server

Note: This procedure should be performed by the customer user on the Prinergy server on site, if the Archive/Purge JTPs are running on a secondary server. The rest of the procedures are performed by Kodak service representatives.

Note: In Prinergy Workflow 8.1.1 and later, you do not need to install the Cloud Agent on the secondary server. In version of Prinergy Workflow that are earlier than 8.1.1, you need to install the Cloud Agent on the secondary server in order to replace the JTPs.

  1. In UADM, stop the Prinergy server if it is running.
  2. Close the UADM.
  3. From the downloaded Prinergy Cloud update Zip file, open the CloudAgentSetup folder, and run the latest CloudServicesSetup_X.XBLD<xxx>.exe file.
  4. Follow the wizard instructions.
  5. Repeat this procedure on every secondary server that runs the Archive/Purge JTPs.
  6. In UADM, start the Prinergy server.
  7. If the secondary server is also the EPM server or a Hot Standby failover server, then the Kodak Cloud Agent service must be stopped and disabled.